The line set.
The two copper pipes between inside and outside. Which one is sweating tells you something.
The line set is the pair of copper tubes running between the outdoor unit and the indoor air handler. Everything the system does passes through them.
The liquid line is the thinner one, uninsulated. It carries warm high pressure liquid refrigerant from the outdoor unit to the metering device.
The suction line is the fatter one, wrapped in black foam insulation. It carries cold low pressure gas back to the compressor.
What each one should feel like
With the system running on a hot day:
The liquid line should be warm, close to outdoor temperature or a little above. Cold or frosty is wrong and suggests a restriction.
The suction line should be cold, and the insulation should feel cool without being wet through. Sweating badly or frosting is a sign.
That is not a diagnosis, it is a quick orientation that costs nothing.
Frost tells you where to look
Frost at the service valve working back along the suction line usually points at the refrigerant charge. Frost starting on the indoor coil and spreading usually points at airflow. The ice guide covers the distinction.
Why insulation matters more here
The suction line insulation does two jobs: it keeps the cold gas from picking up heat on its way back, and it stops condensation forming on cold pipe.
In Phoenix the sun destroys that foam. UV makes it brittle, it cracks, and eventually it falls off in pieces, usually on the outdoor run where nobody looks. Bare suction line in direct sun picks up heat continuously, which costs capacity for as long as it stays bare.
It is cheap to re-insulate and worth doing. Look at the outdoor section of yours.
When a line set is the fault
Leaks at flare fittings and brazed joints, rub-throughs where a line passes through a wall or touches a bracket, and damage from rodents or from somebody’s string trimmer.
Those are refrigerant circuit repairs: recovery, repair, evacuation and recharge. That frequently lands past the one thousand dollar ceiling here, and where it does you get the readings and a referral rather than a quote.
What it looks like going wrong.
There is ice on the outdoor unit.
Winter frost on a heat pump is routine. Summer ice outside is not, and it points somewhere specific.
Read itIce on the AC line, in a Phoenix summer.
A frozen coil in July looks absurd and it is not. It means airflow or refrigerant, and running it that way risks the compressor.
Read it