Ice on the AC line, in a Phoenix summer.
A frozen coil in July looks absurd and it is not. It means airflow or refrigerant, and running it that way risks the compressor.
A coil freezes because it gets too cold, and it gets too cold when it cannot absorb the heat it was expecting. That is counterintuitive on a 115 degree afternoon, and it is still what is happening.
Refrigerant enters the indoor coil cold and boils off as it picks up heat from the air moving across it. Starve it of that air, or run it with less refrigerant than it should have, and the coil surface drops below freezing. Moisture condensing out of the air turns to frost instead of water, the frost closes off the fins, and less air gets through, which makes it colder still. It compounds until the coil is a solid block.
The two causes
Airflow. This is the common one and the cheap one.
- A filter that has not been changed since spring. If the house simply is not cooling and there is no ice, start here instead.
- A blower wheel coated in dust, which looks fine and moves half the air.
- Supply vents closed off in rooms nobody uses, or a return blocked by furniture.
- A crushed or disconnected flex duct in the attic.
Refrigerant charge. This is the other one and it is not cheap.
A sealed system does not consume refrigerant. If it is low, it leaked. A low charge means low pressure, and low pressure means a colder coil. You can top it up and get a few good weeks, and then you are back here with the same symptom and a second bill for the same gas.
Frost that starts at the outdoor service valve and works its way back usually points at the charge. Frost that starts on the indoor coil and spreads usually points at airflow. Neither is a certainty from the driveway.
What to do right now
- Turn cooling off at the thermostat. Set the fan to ON. Room air moving across the coil is the fastest safe way to thaw it.
- Change the filter while it melts.
- Open the closed vents. All of them, including the guest room.
- Put towels down under the air handler. A thawing coil releases more water at once than the drain pan was built for, and it will overflow a drain line that is perfectly clear.
- Wait. Two to four hours, longer if it was solid.
Do not chip the ice off. The fins are soft aluminium and the tubing underneath is thin copper. Do not aim a heat source at it.
Why running it frozen is the costly choice
Refrigerant is supposed to arrive back at the compressor as a gas. When the coil is iced, it does not all boil off, and liquid gets carried back into a pump designed to compress vapour. That is how compressors die, and a compressor is an order of magnitude past anything on the price list here.
If the house is uncomfortable, it is still cheaper to sit at 85 for an afternoon than to replace a compressor in August.
What it costs to find out
If it has frozen once and a filthy filter explains it, you have fixed it for the price of a filter. Say so and keep your money.
If the filter was clean, or it freezes again after a thaw, that is a diagnostic: pressures, temperature split, airflow, and a look at the coil. It is on the price list like everything else, and you get the readings in writing either way.
Where the real answer is a refrigerant leak, the honest version is that finding and fixing the leak is the job, and some of those sit past what can be done here under the one thousand dollar ceiling. If that is where it lands, you will hear it plainly and get handed to a licensed Arizona contractor, at no fee and with no markup.
Questions that come with this one.
How long does it take to thaw?
Two to four hours with the fan running and cooling off. Overnight if the block of ice is a big one. Do not chip at it, and do not point a heat gun at a coil.
It thawed and now it works. Am I fine?
It will freeze again. Thawing removes the ice, not the reason for it. If a new filter was the whole story you are genuinely done; if the filter was clean, something else restricted it and that has not changed.
Can a dirty outdoor unit cause the indoor coil to freeze?
Not directly. A fouled condenser usually shows up as poor cooling and long run times rather than ice. Freezing starts on the low side: airflow across the indoor coil, or a charge that is low because it leaked.
Other things that go wrong.
After a dust storm.
A wall of dust goes somewhere. A good deal of it goes into your condenser.
Read itThe AC quit and it is 115 outside.
Heat in this city is a safety problem before it is a comfort problem. Triage first, diagnosis second.
Read itThermostats, and the C-wire problem.
The wire nobody mentions until the new thermostat is already on the wall.
Read it