After a dust storm.
A wall of dust goes somewhere. A good deal of it goes into your condenser.
A haboob is a wall of dust that can be thousands of feet high, and it has to land somewhere. A fair amount of it lands in the condenser coil on the side of your house, which is a device specifically designed to pull outdoor air through itself.
Nothing dramatic happens that night. The damage is cumulative and quiet.
The morning after
Look through the fins. Stand next to the outdoor unit in daylight and look at the coil at an angle. Clean fins read as a grid you can see through. Loaded fins read as grey felt.
Clear what blew up against it. Bags, palm fronds, tumbleweed, patio cushions. The unit rejects heat sideways and upward and cannot do it into an obstruction.
Look inside the cabinet if the top grille lets you. Storms deposit a surprising amount of gravel and plant matter inside, and loose debris near the fan is worth dealing with before it reaches the blades.
Check the filter indoors. A storm with the system running will load a filter in a single day. If you cannot see light through it, change it.
Listen for new noises. Gravel in the cabinet is the usual cause of a new rattle after a storm. The noises guide covers what each sound means.
Rinsing it yourself
Worth doing, with two rules.
Kill the power first at the disconnect beside the unit. Not the thermostat, the disconnect.
Use a hose, not a pressure washer. The fins are soft aluminium and a pressure washer folds them flat, which permanently reduces airflow through that section. Gentle water, ideally from the inside pushing out.
Where a hose stops working
A rinse moves surface dust. What a Valley storm leaves behind works into the fin pack and, after a few cooling cycles with condensation on it, sets. At that point water runs over the top of it.
That is what the chemical clean is for, and it is the difference between a coil that looks cleaner and one that works again. On the price list as its own line, and cheaper added to a tune-up than bought alone.
Why this is worth your attention
A fouled coil does not announce itself. Head pressure climbs, the compressor works harder for the same cooling, run times stretch, and the house is slightly less comfortable than last year while the bill is slightly higher. Nobody connects the two.
Then on the hottest afternoon of the year the system trips on high pressure, and it looks like a sudden failure. It was not sudden.
Questions that come with this one.
Can I just hose the outdoor unit off myself?
A gentle rinse from a garden hose does no harm and some good, as long as the power is off at the disconnect and you are not blasting the fins with a pressure washer. What a hose will not do is lift material that has packed into the fin pack, which is the part that costs you capacity.
How soon after a storm should I look?
The next morning. Dust that is still loose comes off easily. Dust that has been through a few cooling cycles with condensation on it sets into the fins and needs chemicals.
Does one storm really matter?
One probably not. A season of them absolutely does, and the loss is gradual enough that nobody notices it happening. The system does not break, it just gets worse at its job while the power bill goes up.
Other things that go wrong.
The AC quit and it is 115 outside.
Heat in this city is a safety problem before it is a comfort problem. Triage first, diagnosis second.
Read itThermostats, and the C-wire problem.
The wire nobody mentions until the new thermostat is already on the wall.
Read itThe house is cool and still feels clammy.
Temperature is only half of comfort. In monsoon season the other half shows up.
Read it